Windows在四显示器设置中扩展了2个显示器

可能重复:
显卡所以我可以有4个显示器

我刚安装了ubuntu 11.10以及之前的硬件设置:4个显示器和2个相同的nvidia显卡。

围绕所有4个显示器的窗户工作很好,但是当我最大化窗口时,它总是超过2个屏幕。 (2x twinview)。

我在11.04有一个解决方法,但不记得它是什么…可能你们其中一个人有四个监视器和运行窗口最大化只在一个屏幕上

我的xorg.conf看起来像这样:

# nvidia-settings: X configuration file generated by nvidia-settings # nvidia-settings: version 280.13 (buildd@allspice) Thu Aug 11 20:54:45 UTC 2011 # nvidia-xconfig: X configuration file generated by nvidia-xconfig # nvidia-xconfig: version 280.13 (buildmeister@swio-display-x86-rhel47-03.nvidia.com) Wed Jul 27 17:15:58 PDT 2011 Section "ServerLayout" # Removed Option "Xinerama" "1" # Removed Option "Xinerama" "0" Identifier "Layout0" Screen 0 "Screen0" 0 0 Screen 1 "Screen1" 0 1080 InputDevice "Keyboard0" "CoreKeyboard" InputDevice "Mouse0" "CorePointer" Option "Xinerama" "1" EndSection Section "Files" EndSection Section "InputDevice" # generated from default Identifier "Mouse0" Driver "mouse" Option "Protocol" "auto" Option "Device" "/dev/psaux" Option "Emulate3Buttons" "no" Option "ZAxisMapping" "4 5" EndSection Section "InputDevice" # generated from default Identifier "Keyboard0" Driver "kbd" EndSection Section "Monitor" Identifier "Monitor0" VendorName "Unknown" ModelName "Samsung SMB2220N" HorizSync 31.0 - 80.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Monitor" Identifier "Monitor1" VendorName "Unknown" ModelName "Samsung SMB2220N" HorizSync 31.0 - 80.0 VertRefresh 56.0 - 75.0 Option "DPMS" EndSection Section "Device" Identifier "Device0" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "GeForce GTX 550 Ti" BusID "PCI:2:0:0" EndSection Section "Device" Identifier "Device1" Driver "nvidia" VendorName "NVIDIA Corporation" BoardName "GeForce GTX 550 Ti" BusID "PCI:3:0:0" EndSection Section "Screen" # Removed Option "TwinView" "True" # Removed Option "MetaModes" "nvidia-auto-select, nvidia-auto-select" # Removed Option "metamodes" "CRT-0: nvidia-auto-select 1920x1080 +0+0, CRT-1: nvidia-auto-select 1920x1080 +1920+0" Identifier "Screen0" Device "Device0" Monitor "Monitor0" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "CRT-0" Option "metamodes" "CRT-0: nvidia-auto-select +0+0, CRT-1: nvidia-auto-select +1920+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Screen" # Removed Option "TwinView" "True" # Removed Option "MetaModes" "nvidia-auto-select, nvidia-auto-select" # Removed Option "metamodes" "CRT-0: nvidia-auto-select 1920x1080 +0+0, CRT-1: nvidia-auto-select 1920x1080 +1920+0" Identifier "Screen1" Device "Device1" Monitor "Monitor1" DefaultDepth 24 Option "TwinView" "1" Option "TwinViewXineramaInfoOrder" "CRT-0" Option "metamodes" "CRT-0: nvidia-auto-select +0+0, CRT-1: nvidia-auto-select +1920+0" SubSection "Display" Depth 24 EndSubSection EndSection Section "Extensions" Option "Composite" "Disable" EndSection 

事情不是使用twinview。 使用twinview,窗口系统将您的屏幕识别为两个监视器的总和,并相应地采取行动。 全屏应用程序也会以这种方式跨越两个屏幕。

运行sudo nvidia-settings并禁用双视图。